Sign In | Join Free | My burrillandco.com
Home > POCT HbA1c Analyzer >

Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test

    Buy cheap Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test from wholesalers
     
    Buy cheap Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test from wholesalers
    • Buy cheap Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test from wholesalers

    Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-100
    Certification : IFCC, NGSP, CE
    Price : Negotiation
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100/Day
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test

    Automated POCT HbA1c Analyzer For Glycated Hemoglobin Test


    Intended Use


    Automated POCT HbA1c Analyzer is a device that used for detection of glycosylated hemoglobin (HbA1c) in human blood.

    The LD-100 is a one-step operation HbA1c analyzer. For the measurement of glycated hemoglobin by the well-established borate affinity method. Small amount of sample and easy operation which is aimed to help manage diabetes for patients and professionals in laboratory, clinic and hospital. Flexible workflow, easy to use with lab-quality results. LD-100 helps you to be more efficient in your lab workflow.


    Feature


    Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

    Ease of use: One-step operation the instrument is ready for use.

    • Less than 3-minute test time

    • A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

    • With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

    • Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).




    Reliable

    IFCC calibratorNormalAbnormalNormalAbnormal
    Mean HbA1c%5.49.65.39.2
    CV (%)2.5%1.9%2.4%1.8%

    Performance Parameters

    • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
    • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
    • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
    • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
    • Functions of the analyzer:The function of report output in English; Abnormal alarm function.

    Certificate

    Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin TestAutomated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test


    Quality Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)